Xscf commands m5000 firecracker

These sequence of solaris commands performs the xcp import, xscf update and obp application which make up the xscf. Overview manual 76 pages xscf reference manual 560 pages user manual 450 pages. Unless you create a new user in the sun m4000 xscf, you may only log in as the default user. This command only issues the instruction to poweroff. Security vulnerabilities in early versions of sun sparc. Log into the xscf and verify you have the appropriate privileges.

In a system with redundant xscf units, you have only to connect to the xscf unit on the active side and update the firmware. This command only issues the instruction to poweron. Most commonly used xscf commands cheat sheet the geek. Sun sparc enterprise m5000 server version not applicable and later sun sparc enterprise m900032 server version not applicable and later. Refer to thesun sparc enterprise m4000m5000 servers site planning guide and the sun sparc enterprise equipment rack mounting guide. The extended system control facility unit xscfu is a service processor that operates and administrates both midrange servers. Im administrating an m5000 server and i need to login into the console to run a diagnostic. Mseries extended system control facility xscf command line guide. The sun fire mx000 servers like sun fire m4000, m5000, m8000 or m9000 are the successors of the sun fire f12k, f15k, e20k and e25k systems. Therefore, hardware sentry will connect to the xscf through ssh and execute commands to discover and monitor the status of the hardware components of a sun fire mx000 server. The description of xscf shell command written in this manual is the same as the manual page which appears as a result of man command executed in xscf environment.

Sun sparctm enterprise m3000, m4000, m5000, m8000, m9000. This post will explain how to upgrade the firmware from 1080 to firmware 1117 on m series servers sparc enterprise m3000, m4000, m5000, m8000, and m9000. The output of xscf s command showdomainstatus may cause confusion. The psb is configured either in unixsb mode or quadxsb mode. Fujitsu sparc enterprise m4000 reference manual pdf. Connect serial cable for ser mgt port on the back of the m4000 server 2. Sun m4000 m5000 xscf setup sun xscf m4000 setup for xxxx 1. Sun sparc enterprise m5000 server from the server xscf prompt, run the below. The result of the instruction can be checked by the showlogs power. Basic config xscf sun sparc m5000 basic config xscf sun sparc m5000.

This requires that you be physically present in the front of the server to turn the mode switch. Verify the hardware configuration by using the following commands on the administration console connected to the system control network. How to upgrade firmware on m series oracle servers unixrock. M5000 power supply unit psu replacement procedure 807557 jul 6, 2009 6. I did find out some of the commands however you need a special password. Xscf showboards av xsb r didlsb assignment pwr conn conf test fault cod. Xscf update is started xscfu0,bank1,xcp version1111.

Execute the setdate command with a user account that has the platadm or fieldeng privilege. How to collect xscf snapshot on mseries servers m3000. To determine the version of xcp firmware installed on a system, the following command can be used at the xscf prompt. The intent of this document is to provide the reader with the available versions of the sun sparcr enterprise m3000, m4000, m5000, m8000, and m9000 xcp firmware image software xcp and to inform them how and where to obtain the appropriate images. Basic config xscf sun sparc m5000 share and learn all. Sparc enterprise mx000 servers xscf reference manual. How to upgrade the m4000 xscf firmware solaris commands. Most commonly used xscf commands cheat sheet by admin the extended system control facility unit xscfu is a service processor that operates and administrates both midrange servers. The xscf snapshot command which collects the configuration setup, environmental,logs, errors, and fruid information which are required to perform the diagnosis.

For how to use the man command, please refer toman1 in this manual. In addition, for the detail content of xscf, please refer to sparc enterprise m4000 m5000 m8000m9000 servers. We have purchased over 15 of these boxes for a project and all boot fine except for 1. I just want to share the step by step procedure which will help us lot whenever we getting the same kind of request.

This set of solaris commands configures the sun m4000 xscf including setting up an admin account that gets. Physical system board the psb includes at least 1 cpum, 1 memb and 1 iou on m4000 or m5000 server. In this post we are going to see more about xscf snapshot. Configure the xscf net mgt port with static ip using the following. M5000 xscf flash update september 25, 2012 login as. View and download fujitsu sparc enterprise m4000 reference manual online. After i logon to the xscf prompt of this sun m5000 and did xscf version c xcp, the xscf prompt disappeared. Sun m5000 server suns m500 server has a new management interface card called xscf its vastly different from the sc interface of the other. The firmware upgrade is performed first on the xscf unit on the standby side and then on the active side automatically. Installation task map for sun sparc enterprise m4000m5000 servers step 1 verify power, air conditioning, and floor area requirements. I took over an m5000 and have a jumper server with a nic to connect to the console ip of an m5000.

Mseries extended system control facility xscf command. Sunsparcenterprise m4000m5000m8000m9000 serversxscf referencemanual. It provides a user interface and firmware utility commands known as forth command set. Step by step configuration of the xscf console for the sun sparc m3000 server xscf extended system control facility is used to control, monitor, operate, and service sparc enterprise series servers and domains. Accessing service mode on the sun sparcr enterprise mx000 series platform and clearing faults. Aziz on november 9, 2012 xscf or extended system control facility unit is known as service processor for mseries server. The xscfu diagnoses and starts the entire server, configures domains, offers dynamic reconfiguration, as well as detects and notifies various failures. How to collect xscf snapshot on mseries servers m3000 m4000 m5000 m8000 m9000 by admin snapshot stores the collected data on a remote network host or on an external media device, based upon the use of the t, t or d option. Monitoring sun fire m4000, m5000, m8000 and m9000 servers. Sparc enterprise m8000, sparc enterprise m9000, sparc enterprise m5000. Accessing service mode on the sun sparcr enterprise. Use the setdate command to set the date and time of the xscf clock. Xscf user interfaces 17 xscf monitoring and linkage to other functions 19 time synchronization 112 chapter2 setting up xscf 21.

Performing certain xscf commands on the xscf shell terminal can display the server status so that control and configuration information related to system operation can be viewed. Xscf shell command that outputs the current firmware version information. When i do the showboard command it shows the board in cod mode. Sun sparc enterprise m3000 server getting started guide. I pointed this posting out to the sun tech and am told the only way to fix this issue is for sun to send a tech onsite. To confirm the date and time of the xscf clock, use the showdate command.

At this stage, the domain should restart if post does not detect any further problem. Performing certain xscf commands on the xscf shell terminal can display the. Installing vmware tools from the command line with. Xscf command cheat sheet adduser creates an xscf user account. Sun sparc enterprise m4000m5000 servers getting started.

Xscf configuration doc o n m5000 servers xscf setupplatform. To switch from the xscf console to the ok prompt, enter theconsole d 0 command. Obp parameter is set to offfalse the domain will not automatically reboot and will stop at the ok prompt. Last week i have upgraded latest firmware on m series oracle servers. Sun sparc enterprise m5000 server version not applicable and later all platforms goal. Upgrading the m4000 xscf firmware is a threestep process. Basic config xscf sun sparc m5000 published by rizki a. Domain creation two equal domains set up hardware xscf setupfru x 1 sb 0 xscf setdcl d 0 a 0000 xscf addboard y d 0 c assign 000.

401 832 1213 1501 1516 1536 1099 975 713 1144 807 1359 769 823 1296 188 1020 1320 1272 1341 890 601 324 187 1151 1118 238 916 410 530 960 792 498 677